- Lan Speed Test Server Serial Key Euro Truck Simulator 2
- Lan Speed Test Server Serial Key Generator
- Lan Speed Test Server Serial Key 64-bit
- Lan Speed Test Server Serial Key Windows 10
First, we create a server instance that listens for HTTP requests on port 80. This is the default port for web servers. In the setup, we tell the server what to do with certain HTTP requests. If the URI '/' is requested, the server should reply with a HTTP status code of 200 (Ok) and then send a response with the words 'Hello world!' LAN Speed Test (Lite) The Lite version of LAN Speed Test is a standalone portable executable of 122KB and basically an older free version of the shareware program. It's an easy to use tool for measuring the speed on your LAN by copying a file to another computer that is located on the same local network.
LAN Speed Test v4 is available!
Nov 17, 2017
LAN Speed Test v4 is available!We are happy to announce that LAN Speed Test v4 is now available. This is the much anticipated update to our most popular network tool. LAN Speed Test v4 includes many new features and enhancements, such as availability for Windows and Mac computers, the ability to choose from multiple network connections, a much improved user interface and much more! |
LAN Speed Test's user interface has been greatly improvedPlus it's fully high DPI - aware!As 4k Ultra HD and retina diplays have become more common, LAN Speed Test's user interface can now automatically scale to look great on any screen. No more tiny text and icons on high dpi monitors. |
LAN Speed Test LiteLAN Speed Test and LAN Speed Test (Lite) are now the same download. LAN Speed Test v4 starts in a completely free (Lite) mode. LAN Speed Test (Lite) is fully functional with no nag screens, no time limits, etc. - only some of the more advanced features are disabled. |
Some of LAN Speed Test 4.0 features include..
- Test the speed of your Local Network by testing to/from network shared folders
- Test the speed of your local drives (USB Drives, hard drives, etc.)
- Compatible with LST Server (v1.5 or later) for real network performance results without hard drive limitations – Even test your WAN (Internet) speed with LST Server
- Completely Portable - No installation needed
- Available for Windows and Mac computers
- Ability to choose Network Interface Card for computers with multiple NICs
- Ability to view each packet's results in a chart or by details *
- Email results manually, automatically, or only when under a certain speed *
- Log results to .csv file with user configurable file location. All entries are SQL compatible for easy importing into SQL Server, MySql, etc.) *
- Option to log Avg, Max, & Min automatically *
- View/Edit Log built right into LAN Speed Test *
- Network Scan (see other devices on your network, keep notes about them, etc.) *
- Run multiple tests automatically - any number of tests from 1 sec to 24 hrs apart *
- Open/Save all options and results to .csv file
- Command Line Builder (automatically builds the command line options that you need based on your current settings) *
- Plus lots more!
* Indicates a feature that is available after purchasing a full license for LAN Speed Test
Upgrade Tool is online
Are you eligible for a discounted or free upgrade? Just go here, and type in your serial number for your upgrade details
Name
ipmitool - utility for controlling IPMI-enabled devicesSynopsis
ipmitool [-c|-h|-d N|-v|-V] -Iopen<command>ipmitool [-c|-h|-v|-V] -Ilan-H <hostname> [-p <port>]
[-U <username>]
[-A <authtype>]
[-L <privlvl>]
[-a|-E|-P|-f <password>]
[-o <oemtype>]
[-O <sel oem>]
[-e <esc_char>]
[-N <sec>]
[-R <count>]
<command>
ipmitool [-c|-h|-v|-V] -Ilanplus-H <hostname> [-p <port>]
[-U <username>]
[-L <privlvl>]
[-a|-E|-P|-f <password>]
[-o <oemtype>]
[-O <sel oem>]
[-C <ciphersuite>]
[-Y|[-K|-k <kg_key>]
[-y <hex_kg_key>]
[-e <esc_char>]
[-N <sec>]
[-R <count>]
<command>
Description
This program lets you manage Intelligent Platform Management Interface (IPMI) functions ofeither the local system, via a kernel device driver, or a remote system, using IPMI V1.5 and IPMI v2.0. These functions include printing FRU information, LANconfiguration, sensor readings, and remote chassis power control.IPMI management of a local system interface requires a compatible IPMI kernel driver to be installed and configured. On Linux this driver is calledOpenIPMI and it is included in standard distributions. On Solaris this driver is called BMC and is inclued in Solaris 10. Management of a remotestation requires the IPMI-over-LAN interface to be enabled and configured. Depending on the particular requirements of each system it may be possible to enablethe LAN interface using ipmitool over the system interface.
Options
If no password method is specified then ipmitool will prompt the user for a password. If no password is entered at the prompt, the remote server passwordwill default to NULL.
Security
There are several security issues be be considered before enabling the IPMI LAN interface. Aremote station has the ability to control a system's power state as well as being able to gather certain platform information. To reduce vulnerability it isstrongly advised that the IPMI LAN interface only be enabled in 'trusted' environments where system security is not an issue or where there is a dedicatedsecure 'management network'.Further it is strongly advised that you should not enable IPMI for remote access without setting a password, and that that password should not be the sameas any other password on that system.
When an IPMI password is changed on a remote machine with the IPMIv1.5 lan interface the new password is sent across the network as clear text. Thiscould be observed and then used to attack the remote system. It is thus recommended that IPMI password management only be done over IPMIv2.0 lanplusinterface or the system interface on the local station.
For IPMI v1.5, the maximum password length is 16 characters. Passwords longer than 16 characters will be truncated.
For IPMI v2.0, the maximum password length is 20 characters; longer passwords are truncated.
Commands
ipmitool help
Commands: raw Send a RAW IPMI request and print response
i2c Send an I2C Master Write-Read command and print response
spd Print SPD info from remote I2C device
lan Configure LAN Channels
chassis Get chassis status and set power state
power Shortcut to chassis power commands
event Send events to MC
mc Management Controller status and global enables
sdr Print Sensor Data Repository entries and readings
sensor Print detailed sensor information
fru Print built-in FRU and scan for FRU locators
sel Print System Event Log (SEL)
pef Configure Platform Event Filtering (PEF)
sol Configure and connect IPMIv2.0 Serial-over-LAN
tsol Configure and connect Tyan IPMIv1.5 Serial-over-LAN
isol Configure and connect Intel IPMIv1.5 Serial-over-LAN
user Configure Management Controller users
channel Configure Management Controller channels
session Print session information
sunoem Manage Sun OEM Extensions
kontronoem Manage Kontron OEM Extensions
picmg Run a PICMG/ATA extended command
firewall Configure Firmware Firewall
shell Launch interactive IPMI shell
exec Run list of commands from file
set Set runtime variable for shell and exec
delloem Manage Dell OEM Extensions
echo Used to echo lines to stdout in scripts
ekanalyzer run FRU-Ekeying analyzer using FRU files
ipmitool chassis help
Chassis Commands: status, power, identify, policy, restart_cause, poh, bootdev, bootparam, selftest
ipmitool chassis power help
chassis power Commands: status, on, off, cycle, reset, diag, soft
Instructs the BMC to perform a warm or cold reset.
Display the Management Controller Globally Unique IDentifier.
Displays information about the BMC hardware, including device revision, firmware revision, IPMI version supported, manufacturer ID, and information onadditional device support.
These commands allow a user to view and change the current state of the watchdog timer.
Show current Watchdog Timer settings and countdown state.
Reset the Watchdog Timer to its most recent state and restart the countdown timer.
Turn off a currently running Watchdog countdown timer.
Check on the basic health of the BMC by executing the Get Self Test results command and report the results.
Displays a list of the currently enabled options for the BMC.
Enables or disables the given option. This command is only supported over the system interface according to the IPMI specification. Currentlysupported values for option include:
Receive Message Queue Interrupt
Event Message Buffer Full Interrupt
Event Message Buffer
System Event Logging
OEM-Defined option #0
OEM-Defined option #1
Displays information about the authentication capabilities of the selected channel at the specified privilege level.
1 Callback level
2 User level
3 Operator level
4 Administrator level
5
Displays information about the selected channel. If no channel is given it will display information about the currently used channel.
> ipmitool channel info
Channel 0xf info:
Channel Medium Type : System Interface
Channel Protocol Type : KCS
Session Support : session-less
Active Session Count : 0
Protocol Vendor ID : 7154
Configure the given userid as the default on the given channel number. When the given channel is subsequently used, the user is identified implicitly by thegiven userid.
Configure user access information on the given channel for the given userid.
Displays the list of cipher suites supported for the given application (ipmi or sol) on the given channel.
Sets K_g key to given value. Use plain to specify key as simple ASCII string. Use hex to specify key as sequence of hexadecimalcodes of ASCII charactes. I.e. following two examples are equivalent:
ipmitool channel setkg plainPASSWORD
ipmitool channel setkg hex 50415353574F5244Displays information regarding the high-level status of the system chassis and main power subsystem.
This command will return the Power-On Hours counter.
Control the front panel identify light. Default interval is 15 seconds. Use 0 to turn off. Use 'force' to turn on indefinitely.
Query the chassis for the cause of the last system restart.
Check on the basic health of the BMC by executing the Get Self Test results command and report the results.
Set the chassis power policy in the event power failure.
Return supported policies.
Turn on when power is restored.
Returned to previous state when power is restored.
Stay off after power is restored.
Performs a chassis control command to view and change the power state.
Show current chassis power status.
Power up chassis. Download astm standards for free.
Power down chassis into soft off (S4/S5 state). WARNING: This command does not initiate a clean shutdown of the operating system prior to poweringdown the system.
Provides a power off interval of at least 1 second. No action should occur if chassis power is in S4/S5 state, but it is recommended to check power statefirst and only issue a power cycle command if the system power is on or in lower sleep state than S4/S5.
This command will perform a hard reset.
Pulse a diagnostic interrupt (NMI) directly to the processor(s).
Initiate a soft-shutdown of OS via ACPI. This can be done in a number of ways, commonly by simulating an overtemperture or by simulating a power buttonpress. It is necessary for there to be Operating System support for ACPI and some sort of daemon watching for events for this soft power to work.
Request the system to boot from an alternate boot device on next reboot. The clear-cmos option, if supplied, will instruct the BIOS to clear its CMOSon the next reboot. Various options may be used to modify the boot device settings. Run 'bootdev none options=help' for a list of available boot devicemodifiers/options.
Do not change boot device
Force PXE boot
Force boot from BIOS default boot device
Force boot from BIOS default boot device, request Safe Mode
Force boot from diagnostic partition
Force boot from CD/DVD
Force boot into BIOS setup
Get or set various system boot option parameters.
Get boot parameter. Currently supported values for <param #> are:
0 - Set
In Progress
1 - Service Partition Selector
2 - Service Partition Scan
3 - BMC Boot Flag Valid Bit Clearing
4 - Boot Info Acknowledge
5 - Boot
Flags
6 - Boot Initiator Info
7 - Boot Initiator Mailbox
Set boot parameter.
Force PXE boot
Force boot from default hard-drive
Force boot from default hard-drive, request Safe Mode
Force boot from diagnostic partition
Force boot from CD/DVD
Force boot into BIOS setup
ipmitool fru read
- frushow <xx=filename>
Convert a binary FRU file into human readable text format. Use -v option to get more display information.
Display only matched results of Ekeying match between an On-Carrier device and an AMC module or between 2 AMC modules. Example: > ipmitool ekanalyzersummary match oc=fru b1=amcB1 a2=amcA2
On-Carrier Device vs AMC slot B1
AMC slot B1 port 0 > On-Carrier Device 0 port 16
Matching Result
- From On-Carrier Device ID 0
-Channel ID 11 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot B1
-Channel ID 0 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
AMC slot B1 port 1 > On-Carrier Device 0 port 12
Matching Result
- From On-Carrier Device ID 0
-Channel ID 6 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot B1
-Channel ID 1 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
On-Carrier Device vs AMC slot A2
AMC slot A2 port 0 > On-Carrier Device 0 port 3
Matching Result
- From On-Carrier Device ID 0
-Channel ID 9 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot A2
-Channel ID 0 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
AMC slot B1 vs AMC slot A2
AMC slot A2 port 2 > AMC slot B1 port 2
Matching Result
- From AMC slot B1
-Channel ID 2 || Lane 0: enable
-Link Type: AMC.3 Storage
-Link Type extension: Serial Attached SCSI (SAS/SATA)
-Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
- To AMC slot A2
-Channel ID 2 || Lane 0: enable
-Link Type: AMC.3 Storage
-Link Type extension: Serial Attached SCSI (SAS/SATA)
-Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
Display the unmatched results of Ekeying match between an On-Carrier device and an AMC module or between 2 AMC modules
Display both matched result and unmatched results of Ekeying match between two cards or two modules.
The delloem commands provide information on Dell-specific features.
Sets the drive backplane LEDs for a device.
{b:d.f} = PCI Address of device (eg. 06:00.0)
{state} = one or more of the following:
online | present | hotspare | identify | rebuilding | fault | predict | critical | failed
set {mode}|{lcdqualifier}|{errordisplay}
Allows you to set the LCD mode and user-defined string.
{none}|{modelname}|{ipv4address}|{macaddress}|
{systemname}|{servicetag}|{ipv6address}|
{ambienttemp}|{systemwatt}|{assettag}|
{userdefined}
Allows you to set the LCD display mode to any of the preceding parameters.
{watt}|{btuphr}|
{celsius}|{fahrenheit}
Allows you to set the unit for the system ambient temperature mode.
{sel}|{simple}
Allows you to set the error display.
Displays the LCD screen information.
Allows you to set the vKVM status to active or inactive. When it is active and session is in progress, a message appears on LCD.
Displays the LCD status for vKVM display active or inactive and Front Panel access mode (viewandmodify, view-only or disabled).
Allows to set backplane LED state.
PCI Bus:Device.Function of drive (lspci format).
Sets the LED state (present, online, hotspare, identify, rebuilding, fault, predict, critical or failed). More than one state can be specified, thefinal state is composed as logical OR of all specified states.
Displays the information about the system NICs.
Displays the NIC MAC address and status of all NICs. It also displays the DRAC/iDRAC MAC address.
Displays the selected NICs MAC address and status.
Displays the information of Lan.
Sets the NIC selection mode (dedicated, shared with lom1, shared with lom2,shared with lom3,shared with lom4,shared with failover lom1,shared with failoverlom2,shared with failover lom3,shared with failover lom4,shared with Failover all loms, shared with Failover None).
Returns the current NIC selection mode (dedicated, shared with lom1, shared with lom2, shared with lom3, shared with lom4,shared with failover lom1, sharedwith failover lom2,shared with failover lom3,shared with failover lom4,shared with Failover all loms,shared with Failover None).
Returns the current active NIC (dedicated, LOM1, LOM2, LOM3 or LOM4).
Displays power tracking statistics.
Reset cumulative power reading.
Reset peak power reading.
|
Displays the power consumption in watt or btuphr.
|
Displays the power consumption history in watt or btuphr.
|
Displays the power cap in watt or btuphr.
|btuphr|percent>
Allows you to set the power cap in watt, BTU/hr or percentage.
Enables set power cap.
Disables set power cap.
Shows Extended SD Card information
- vFlash info Card
event <predefined event numberN> Send a pre-defined test event to the System Event Log. The following events are included as a means to test the functionality of the System Event Logcomponent of the BMC (an entry will be added each time the event N command is executed).
Currently supported values for N are:
1 Temperature: Upper Critical: Going High
2 Voltage Threshold: Lower Critical: Going Low
3 Memory: Correctable ECCNOTE: These pre-defined events will likely not produce 'accurate' SEL records for a particular system because they will not be correctly tied to avalid sensor number, but they are sufficient to verify correct operation of the SEL.
file <filename> Event log records specified in <filename> will be added to the System Event Log.
The format of each line in the file is as follows:
<{EvM Revision} {Sensor Type} {Sensor Num} {Event Dir/Type} {Event Data 0} {Event Data 1} {Event Data2}>[# COMMENT]
e.g.: 0x4 0x2 0x60 0x1 0x52 0x0 0x0 # Voltage threshold: Lower Critical: Going Low
EvM Revision - The 'Event Message Revision' is 0x04 for messages that comply with the IPMI 2.0 Specification and 0x03 for messages that comply withthe IPMI 1.0 Specification.
Sensor Type - Indicates the Event Type or Class.
Sensor Num - Represents the 'sensor' within the management controller that generated the Event Message.
Event Dir/Type - This field is encoded with the event direction as the high bit (bit 7) and the event type as the low 7 bits. Event direction is 0for an assertion event and 1 for a deassertion event.
See the IPMI 2.0 specification for further details on the definitions for each field.
<sensorid> <list> Get a list of all the possible Sensor States and pre-defined Sensor State Shortcuts available for a particular sensor. sensorid is the characterstring representation of the sensor and must be enclosed in double quotes if it includes white space. Several different commands including ipmitool sensorlist may be used to obtain a list that includes the sensorid strings representing the sensors on a given system.
> ipmitool -I open event 'PS 2T Fan Fault' list
Finding sensor PS 2T Fan Fault.. ok
Sensor States:
State DeassertedState Asserted
Sensor State Shortcuts:
present absentassert deassert
limit nolimit
For the newcomers, here, we released 3 months ago a vanilla version of the HD mod found on resurgence and developped by Mir Drualga and Planqi.Not only this enables two new screen resolutions that are better suited for modern computer screen ratios (1344x700 and 1068x600) but it also handles Maphack injection as one launch the client. Make sure your Diablo II is running on patch 1.13d as seen below, if you are running a different verison place 114d109Gamegame.exe into your Diablo II folder and run 114d109GameLODPatch113d.exe ###1) Open up the 114d.rar and place D2BS.dll from 114dd2bs into your kolbotd2bs folder. Only supports Diablo II version 1.13c! Maphack allows players to see the entire map as soon as they enter an area, rather than having to explore the area first to discover the layout of the level. It allows you to see the location and full equipment of other players, as well as showing all of the monsters, shrines, chests, and more on the. Diablo II 1.14d Kolbot Setup Blizzard Response to Diablo 2 Bots Patch 1.14 + (Discussion) Fastest Killing Builds in Diablo 2 (Information, History Walk through) - 디아블로 2. D2MR working Diablo II maphack 2020! Watch; Next video playing soon. Click to cancel. Autoplay has been paused. Click to watch next video. First published at 03:34 UTC on April 13th, 2019. How to break a realmdown aka socks5 setup for Diablo 2 (proxy) 6 months, 3 weeks ago. Diablo 2: 4x Ebugged Fortitude Rolls. 9 months, 2 weeks ago. Diablo 2 lod maphack 1.14d.
fail nofail
yes no
on off
up down
<sensorid> <sensor state> [<direction>] Generate a custom event based on existing sensor information. The optional event direction can be either assert (the default) ordeassert.
> ipmitool event 'PS 2T Fan Fault' 'State Asserted'
Finding sensor PS 2T Fan Fault.. ok
0 | Pre-Init Time-stamp | Fan PS 2T Fan Fault | State Asserted> ipmitool event 'PS 2T Fan Fault' 'State Deasserted'
Finding sensor PS 2T Fan Fault.. ok
0 | Pre-Init Time-stamp | Fan PS 2T Fan Fault | State Dessertedexec <filename> Execute ipmitool commands from filename. Each line is a complete command. The syntax of the commands are defined by the COMMANDS section inthis manpage. Each line may have an optional comment at the end of the line, delimited with a '#' symbol.e.g., a command file with two lines:
sdr list # get a list of sdr records
get a list of sel records
sel list #fru Read all Field Replaceable Unit (FRU) inventory data and extract such information as serial number, part number, asset tags, and short strings describingthe chassis, board, or product.
read <fru id> <fru file> fru id is the digit ID of the FRU (see output of 'fru print'). fru file is the absolute pathname of a file in which to dump the binary FRUdata pertaining to the specified FRU entity.
write <fru id> <fru file> fru id is the digit ID of the FRU (see output of 'fru print'). fru file is the absolute pathname of a file from which to pull the binary FRUdata before uploading it to the specified FRU.
upgEkey <fru id> <fru file> Update a multirecord FRU location. fru id is the digit ID of the FRU (see output of 'fru print'). fru file is the absolute pathname of a filefrom which to pull the binary FRU data to upload into the specified multirecord FRU entity.
edit <fru id> This command provides interactive editing of some supported records, namely PICMG Carrier Activation Record. fru id is the digit ID of the FRU (seeoutput of 'fru print'); default is 0.
edit <fru id> field <section> <index> <string> This command may be used to set a field string to a new value. It replaces the FRU data found at index in the specified section with thesupplied string.
fru id is the digit ID of the FRU (see output of 'fru print'). <section> is a string which refers to FRU Inventory Information Storage Areas and may be refer to: c FRU Inventory Chassis Info Area b FRU Inventory Board Info Area p FRU Inventory Product Info Area <index> specifies the field number. Field numbering starts on the first 'english text' field type. For instance in the <board>info area field '0' is <Board Manufacturer> and field '2' is <Board Serial Number>; see IPMI Platform Management FRU InformationStorage Definition v1.0 R1.1 for field locations. <string> must be the same length as the string being replaced and must be 8-bit ASCII (0xCx). edit <fru id> oem iana <record> <format> [<args>] This command edits the data found in the multirecord area. Support for OEM specific records is limited.
firewall This command supports the Firmware Firewall capability. It may be used to add or remove security-based restrictions on certain commands/commandsub-functions or to list the current firmware firewall restrictions set on any commands. For each firmware firewall command listed below, parameters may beincluded to cause the command to be executed with increasing granularity on a specific LUN, for a specific NetFn, for a specific IPMI Command, and finally fora specific command's sub-function (see Appendix H in the IPMI 2.0 Specification for a listing of any sub-function numbers that may be associated with aparticular command).
Parameter syntax and dependencies are as follows:
[<channelH>] [<lunL> [ <netfnN> [<commandC [<subfnS>]]]]
Note that if 'netfn <N>' is specified, then 'lun <L>' must also be specified; if 'command <C>' is specified, then'netfn <N>' (and therefore 'lun <L>') must also be specified, and so forth.
'channel <H>' is an optional and standalone parameter. If not specified, the requested operation will be performed on the current channel. Notethat command support may vary from channel to channel.
Firmware firewall commands:
info [<Parms as described above>] List firmware firewall information for the specified LUN, NetFn, and Command (if supplied) on the current or specified channel. Listed information includesthe support, configurable, and enabled bits for the specified command or commands.
Some usage examples:
info [<channel H>] [<lun L>] This command will list firmware firewall information for all NetFns for the specified LUN on either the current or the specified channel.
Free sim unlock code for huawei. After selecting your model, click on the 'Unlock' button.2. After selecting your device, the website will ask you to provide the IMEI of your phone.3.
info [<channel H>] [<lun L> [ <netfn N> ] This command will print out all command information for a single LUN/NetFn pair.
info [<channel H>] [<lun L> [ <netfn N> [<command C] ]] This prints out detailed, human-readable information showing the support, configurable, and enabled bits for the specified command on the specifiedLUN/NetFn pair. Information will be printed about each of the command subfunctions.
info [<channel H>] [<lun L> [ <netfn N> [<command C [<subfn S>]]]] Print out information for a specific sub-function.
enable [<Parms as described above>] This command is used to enable commands for a given NetFn/LUN combination on the specified channel.
disable [<Parms as described above>] [force] This command is used to disable commands for a given NetFn/LUN combination on the specified channel. Great care should be taken if using the 'force' optionso as not to disable the 'Set Command Enables' command.
reset [<Parms as described above>] This command may be used to reset the firmware firewall back to a state where all commands and command sub-functions are enabled.
i2c <i2caddr> <read bytes> [<write data>] This command may be used to execute raw I2C commands with the Master Write-Read IPMI command.
isol info Retrieve information about the Intel IPMI v1.5 Serial-Over-LAN configuration.
set <parameter> <value> Configure parameters for Intel IPMI v1.5 Serial-over-LAN.
Valid parameters and values are: enabled true, false. privilege-level user, operator, admin, oem. bit-rate 9.6, 19.2, 38.4, 57.6, 115.2. activate Causes ipmitool to enter Intel IPMI v1.5 Serial Over LAN mode. An RMCP+ connection is made to the BMC, the terminal is set to raw mode, and user input issent to the serial console on the remote server. On exit, the the SOL payload mode is deactivated and the terminal is reset to its original settings.
Special escape sequences are provided to control the SOL session:
~. Terminate connection ~^Z Suspend ipmitool ~^X Suspend ipmitool, but don't restore tty on restart ~B Send break ~~ Send the escape character by typing it twice ~? Print the supported escape sequences Note that escapes are only recognized immediately after newline.
kontronoem OEM commands specific to Kontron devices.
setsn Set FRU serial number.
setmfgdate Set FRU manufacturing date.
nextboot <boot device> Select the next boot order on the Kontron CP6012.
lan These commands will allow you to configure IPMI LAN channels with network information so they can be used with the ipmitool lan and lanplusinterfaces. NOTE: To determine on which channel the LAN interface is located, issue the 'channel info number' command until you come across avalid 802.3 LAN channel. For example:
> ipmitool -I open channel info 1
Channel 0x1 info:
Channel Medium Type : 802.3 LAN
Channel Protocol Type : IPMB-1.0
Session Support : session-based
Active Session Count : 8
Protocol Vendor ID : 7154print [<channel>] Print the current configuration for the given channel. The default will print information on the first found LAN channel.
set <channel number> <command> <parameter> Set the given command and parameter on the specified channel. Valid command/parameter options are:
ipaddr <x.x.x.x> Set the IP address for this channel.
netmask <x.x.x.x> Set the netmask for this channel.
macaddr <xx:xx:xx:xx:xx:xx> Set the MAC address for this channel.
defgw ipaddr <x.x.x.x> Set the default gateway IP address.
defgw macaddr <xx:xx:xx:xx:xx:xx> Set the default gateway MAC address.
bakgw ipaddr <x.x.x.x> Set the backup gateway IP address.
bakgw macaddr <xx:xx:xx:xx:xx:xx> Set the backup gateway MAC address.
password <pass> Set the null user password. https://mintingperse1988.mystrikingly.com/blog/word-password-recovery-serial-key.
snmp <community string> Set the SNMP community string.
user Enable user access mode for userid 1 (issue the 'user' command to display information about userids for a given channel).
access <on|off> Set LAN channel access mode.
alert <on|off> Enable or disable PEF alerting for this channel.
ipsrc <source> Set the IP address source:
none unspecified
static manually configured static IP address
dhcp address obtained by BMC running DHCP
bios address loaded by BIOS or system softwarearp respond <on|off> Set BMC generated ARP responses.
arp generate <on|off>
Set BMC generated gratuitous ARPs.
Set BMC generated gratuitous ARP interval.
Disable VLAN operation or enable VLAN and set the ID.
ID: value of the virtual lan identifier between 1 and 4094 inclusive.
Set the priority associated with VLAN frames.
ID: priority of the virtual lan frames between 0 and 7 inclusive.
Set the valid authtypes for a given auth level.
Levels: callback, user, operator, admin
Types: none, md2, md5, password, oem
Correlates cipher suite numbers with the maximum privilege level that is allowed to use it. In this way, cipher suites can restricted to users with a givenprivilege level, so that, for example, administrators are required to use a stronger cipher suite than normal users.
The format of privlist is as follows. Each character represents a privilege level and the character position identifies the cipher suite number. Forexample, the first character represents cipher suite 1 (cipher suite 0 is reserved), the second represents cipher suite 2, and so on. privlist must be15 characters in length.
Characters used in privlist and their associated privilege levels are:
X Cipher Suite Unused
c CALLBACK
u USER
o OPERATOR
a ADMIN
O OEM
So, to set the maximum privilege for cipher suite 1 to USER and suite 2 to ADMIN, issue the following command:
> ipmitool -I interface lan set
channel cipher_privs uaXXXXXXXXXXXXX
Print alert information for the specified channel and destination. The default will print all alerts for all alert destinations on the first found LANchannel.
Set an alert on the given LAN channel and destination. Alert Destinations are listed via the 'lan alert print' command. Valid command/parameteroptions are:
Set alert IP address.
Set alert MAC address.
Set the channel gateway to use for alerts.
Set Alert Acknowledge on or off.
Set the destination type as PET or OEM.
Set ack timeout or unack retry interval.
Set the number of alert retries.
Retrieve information about the IP connections on the specified channel. The default will retrieve statistics on the first found LAN channel.
Clear all IP/UDP/RMCP Statistics to 0 on the specified channel. The default will clear statistics on the first found LAN channel.
This command will query the BMC and print information about the PEF supported features.
This command prints the current PEF status (the last SEL entry processed by the BMC, etc).
This command lists the PEF policy table entries. Each policy entry describes an alert destination. A policy set is a collection of table entries. PEF alertactions reference policy sets.
This command lists the PEF table entries. Each PEF entry relates a sensor event to an action. When PEF is active, each platform event causes the BMC to scanthis table for entries matching the event, and possible actions to be taken. Actions are performed in priority order (higher criticality first).
Run a PICMG/ATA extended command. Get PICMG properties may be used to obtain and print Extension major version information, PICMG identifier, FRU Device IDand Max FRU Device ID.
Get address information. This command may return information on the Hardware address, IPMB-0 Address, FRU ID, Site/Entity ID, and Site/Entity Type.
Set various control options:
Activate the specified FRU.
Deactivate the specified FRU.
Get FRU activation policy.
Set FRU activation policy. lockmask is 1 or 0 to indicate action on the deactivation or activation locked bit respectively. lock is 1 or 0 toset/clear locked bit.
Get or set various port states. See usage for parameter details.
Shortcut to the chassis power commands. See the chassis power commands for usage information.
This will allow you to execute raw IPMI commands. For example to query the POH counter with a raw command:
> ipmitool -v raw 0x0 0xf
RAW REQ (netfn=0x0 cmd=0xf data_len=0)
RAW RSP (5 bytes)
3c 72 0c 00 00
Prints information for sensor data records specified by sensor id.
This command will query the BMC for Sensor Data Record (SDR) Repository information.
This command will display all records from the SDR Repository of a specific type. Run with type list (or simply with no type) to see the list ofavailable types. For example to query for all Temperature sensors:
> ipmitool sdr type Temperature
Baseboard Temp | 30h | ok | 7.1 | 28 degrees C
FntPnl Amb Temp | 32h | ok | 12.1 | 24 degrees C
Processor1 Temp | 98h | ok | 3.1 | 57 degrees C
Processor2 Temp | 99h | ok | 3.2 | 53 degrees C
This command will read the Sensor Data Records (SDR) and extract sensor information of a given type, then query each sensor and print its name, reading, andstatus. If invoked as elist then it will also print sensor number, entity id and instance, and asserted discrete states.
The default output will only display full and compact sensor types, to see all sensors use the all type with this command.
All SDR records (Sensor and Locator)
Full Sensor Record
Compact Sensor Record
Event-Only Sensor Record
Management Controller Locator Record
FRU Locator Record
Displays all sensors associated with an entity. Get a list of valid entity ids on the target system by issuing the sdr elist command. A list of allentity ids can be found in the IPMI specifications.
Dumps raw SDR data to a file. This data file can then be used as a local SDR cache of the remote managed system with the -S option onthe ipmitool command line. This can greatly improve performance over system interface or remote LAN.
Create the SDR Repository for the current configuration. Will perform a 'Clear SDR Repository' command so be careful.
Fill the SDR Repository using records stored in a binary data file. Will perform a 'Clear SDR Repository' command so be careful.
NOTE: System Event Log (SEL) entry-times are displayed as 'Pre-Init Time-stamp' if the SEL clock needs to be set. Ensure that the SEL clock is accurate byinvoking the sel time get and sel time set commands.
This command will query the BMC for information about the System Event Log (SEL) and its contents.
This command will clear the contents of the SEL. It cannot be undone so be careful.
When this command is invoked without arguments, the entire contents of the System Event Log are displayed. If invoked as elist (extended list) itwill also use the Sensor Data Record entries to display the sensor ID for the sensor that caused each event. Note this can take a long time over thesystem interface.
Displays the first count (least-recent) entries in the SEL. If count is zero, all entries are displayed.
Displays the last count (most-recent) entries in the SEL. If count is zero, all entries are displayed.
Delete one or more SEL event records.
Read event entries from a file and add them to the SEL. New SEL entries area added onto the SEL after the last record in the SEL. Record added is of type 2and is automatically timestamped.
Print information on the specified SEL Record entry.
Save SEL records to a text file that can be fed back into the event file ipmitool command. This can be useful for testing Event generation bybuilding an appropriate Platform Event Message file based on existing events. Please see the available help for the 'event file ..' command for a descriptionof the format of this file.
Save SEL records to a file in raw, binary format. This file can be fed back to the sel readraw ipmitool command for viewing.
Read and display SEL records from a binary file. Such a file can be created using the sel writeraw ipmitool command.
Displays the SEL clock's current time.
Sets the SEL clock. Future SEL entries will use the time set by this command. <time string> is of the form 'MM/DD/YYYY HH:MM:SS'. Note thathours are in 24-hour form. It is recommended that the SEL be cleared before setting the time.
Lists sensors and thresholds in a wide table format.
Prints information for sensors specified by name.
This allows you to set a particular sensor threshold value. The sensor is specified by name.
unr Upper Non-Recoverable
ucr Upper Critical
unc Upper Non-Critical
lnc Lower Non-Critical
lcr Lower Critical
This allows you to set all lower thresholds for a sensor at the same time. The sensor is specified by name and the thresholds are listed in order of LowerNon-Recoverable, Lower Critical, and Lower Non-Critical.
Download ace combat 7 for android. This app ' Guide for Ace Combat 7 ' is specially designed for you. Here in this app you'll read complete guide about Ace combat 7 missions. Check it out you'll love it.
This allows you to set all upper thresholds for a sensor at the same time. The sensor is specified by name and the thresholds are listed in order of UpperNon-Critical, Upper Critical, and Upper Non-Recoverable.
Get information about the specified session(s). You may identify sessions by their id, by their handle number, by their active status, or by using thekeyword 'all' to specify all sessions.
This command will launch an interactive shell which you can use to send multiple ipmitool commands to a BMC and see the responses. This can beuseful instead of running the full ipmitool command each time. Some commands will make use of a Sensor Data Record cache and you will see marked improvement inspeed if these commands are able to reuse the same cache in a shell session. LAN sessions will send a periodic keepalive command to keep the IPMI session fromtiming out.
Retrieve information about the Serial-Over-LAN configuration on the specified channel. If no channel is given, it will display SOL configuration data forthe currently used channel.
Enable, disable or show status of SOL payload for the user on the specified channel.
Configure parameters for Serial Over Lan. If no channel is given, it will display SOL configuration data for the currently used channel. Configurationparameter updates are automatically guarded with the updates to the set-in-progress parameter.
Causes ipmitool to enter Serial Over LAN mode, and is only available when using the lanplus interface. An RMCP+ connection is made to the BMC, the terminalis set to raw mode, and user input is sent to the serial console on the remote server. On exit,the the SOL payload mode is deactivated and the terminal isreset to its original settings.
Special escape sequences are provided to control the SOL session:
Note that escapes are only recognized immediately after newline.
Deactivates Serial Over LAN mode on the BMC. Exiting Serial Over LAN mode should automatically cause this command to be sent to the BMC, but in the case ofan unintentional exit from SOL mode, this command may be necessary to reset the state of the BMC.
This command may be used to read SPD (Serial Presence Detect) data using the I2C Master Write-Read IPMI command.
Lan Speed Test Server Serial Key Euro Truck Simulator 2
These commands provide a way to get and set the status of LEDs on a Sun Microsystems server. Use 'sdr list generic' to get a list of devices that arecontrollable LEDs. The ledtype parameter is optional and not necessary to provide on the command line unless it is required by hardware.
Get status of a particular LED described by a Generic Device Locator record in the SDR. A sensorid of all will get the status of all available LEDS.
Set status of a particular LED described by a Generic Device Locator record in the SDR. A sensorid of all will set the status of all available LEDSto the specified ledmode and ledtype.
OFF Off
ON Steady On
STANDBY 100ms on 2900ms off blink rate
SLOW 1HZ blink rate
FAST 4HZ blink rate
OK2RM Ok to Remove
SERVICE Service Required
ACT Activity
LOCATE Locate
Set system fan speed (PWM duty cycle).
This command will allow you to specify an SSH key to use for a particular user on the Service Processor. This key will be used for CLI logins to the SP andnot for IPMI sessions. View available users and their userids with the 'user list' command.
This command will delete the SSH key for a specified userid.
This command allows Serial-over-LAN sessions to be established with Tyan IPMIv1.5 SMDC such as the M3289 or M3290. The default command run with no argumentswill establish default SOL session back to local IP address. Optional arguments may be supplied in any order.
Send receiver IP address to SMDC which it will use to send serial traffic to. By default this detects the local IP address and establishes two-way session.Format of ipaddr is XX.XX.XX.XX
Configure UDP port to receive serial traffic on. By default this is 6230.
Confiure SOL session as read-only or read-write. Sessions are read-write by default.
Displays a summary of userid information, including maximum number of userids, the number of enabled users, and the number of fixed names defined.
Displays a list of user information for all defined userids.
Lan Speed Test Server Serial Key Generator
Sets the username associated with the given userid.
Sets the password for the given userid. If no password is given, the password is cleared (set to the NULL password). Be careful when removing passwords fromadministrator-level accounts.
Disables access to the BMC by the given userid.
Enables access to the BMC by the given userid.
Set user privilege level on the specified channel. If the channel is not specified, the current channel will be used.
Determine whether a password has been stored as 16 or 20 bytes.
Open Interface
The ipmitool open interface utilizes the OpenIPMI kernel device driver. This driveris present in all modern 2.4 and all 2.6 kernels and it should be present in recent Linux distribution kernels. There are also IPMI driver kernel patches fordifferent kernel versions available from the OpenIPMI homepage.The required kernel modules is different for 2.4 and 2.6 kernels. The following kernel modules must be loaded on a 2.4-based kernel in order for ipmitool towork:
- ipmi_msghandler
- Incoming and outgoing message handler for IPMI interfaces.
- ipmi_si
- An IPMI system interface driver for the message handler. This module supports various IPMI system interfaces such as KCS, BT, SMIC, and even SMBus in 2.6kernels.
- ipmi_devintf
- Linux character device interface for the message handler.
Once the required modules are loaded there will be a dynamic character device entry that must exist at /dev/ipmi0. For systems that use devfs or udevthis will appear at /dev/ipmi/0.
To create the device node first determine what dynamic major number it was assigned by the kernel by looking in /proc/devices and checking for theipmidev entry. Usually if this is the first dynamic device it will be major number 254 and the minor number for the first system interface is0 so you would create the device entry with:
mknod /dev/ipmi0
c 254 0
ipmitool includes some sample initialization scripts that can perform this task automatically at start-up.
In order to have ipmitool use the OpenIPMI device interface you can specifiy it on the command line:
ipmitool -Iopen <command>
Bmc Interface
The ipmitool bmc interface utilizes the bmc device driver as provided by Solaris 10and higher. In order to force ipmitool to make use of this interface you can specify it on the command line:ipmitool -Ibmc <command>
The following files are associated with the bmc driver:
- Lan Speed Test Server Serial Key 64-bitlan interface, the lanplus interface communicates with the BMCover an Ethernet LAN connection using UDP under IPv4. The difference is that the lanplus interface uses the RMCP+ protocol as described in the IPMI v2.0specification. RMCP+ allows for improved authentication and data integrity checks, as well as encryption and the ability to carry multiple types of payloads.Generic Serial Over LAN support requires RMCP+, so the ipmitool sol activate command requires the use of the lanplus interface.
- Example 1: Listing remote sensors
- Example 2: Displaying status of a remote sensor
- Example 3: Displaying the power status of a remote chassis
- Example 4: Controlling the power on a remote chassis
RMCP+ session establishment uses a symmetric challenge-response protocol called RAKP (Remote Authenticated Key-Exchange Protocol) which allows thenegotiation of many options. ipmitool does not yet allow the user to specify the value of every option, defaulting to the most obvious settings marked asrequired in the v2.0 specification. Authentication and integrity HMACS are produced with SHA1, and encryption is performed with AES-CBC-128. Role-level loginsare not yet supported.
ipmitool must be linked with the OpenSSL library in order to perform the encryption functions and support the lanplus interface. If therequired packages are not found it will not be compiled in and supported.
You can tell ipmitool to use the lanplus interface with the -Ilanplus option:
ipmitool -Ilanplus-H <hostname> [-U <username>] [-P <password>]<command>
A hostname must be given on the command line in order to use the lan interface with ipmitool. With the exception of the -A and -C options therest of the command line options are identical to those available for the lan interface.
The -C option allows you specify the authentication, integrity, and encryption algorithms to use for for lanplus session based on the ciphersuite ID found in the IPMIv2.0 specification in table 22-19. The default cipher suite is 3 which specifies RAKP-HMAC-SHA1 authentication, HMAC-SHA1-96integrity, and AES-CBC-128 encryption algorightms.
Free Interface
The ipmitool free interface utilizes the FreeIPMI libfreeipmi drivers.
You can tell ipmitool to use the FreeIPMI interface with the -I option:
ipmitool -Ifree <command>
Imb Interface
The ipmitool imb interface supports the Intel IMB (Intel Inter-module Bus) Interface through the /dev/imb device.
You can tell ipmitool to use the IMB interface with the -I option:
ipmitool -Iimb <command>
Examples
> ipmitool -I lan -H 1.2.3.4 -f passfile sdr list
Baseboard 1.25V | 1.24 Volts | ok
Baseboard 2.5V | 2.49 Volts | ok
Baseboard 3.3V | 3.32 Volts | ok
> ipmitool -I lan -H 1.2.3.4 -f passfile sensor get 'Baseboard 1.25V'
Locating sensor record..
Sensor ID : Baseboard 1.25V (0x10)
Sensor Type (Analog) : Voltage
Sensor Reading : 1.245 (+/- 0.039) Volts
Status : ok
Lower Non-Recoverable : na
Lower Critical : 1.078
Lower Non-Critical : 1.107
Upper Non-Critical : 1.382
Upper Critical : 1.431
Upper Non-Recoverable : na
> ipmitool -I lan -H 1.2.3.4 -f passfile chassis power status
Chassis Power is on
> ipmitool -I lan -H 1.2.3.4 -f passfile chassis power on
Chassis Power Control: Up/On